Sensor adjustment with Teach-in procedure
Set detect point
Place object at position
Press push-button for about
3 s until LEDs flash
simultaneously
both LEDs: flash
mutually
Press push-button for
about 1 s
Set window mode
Place object at position
Press push-button for about
3 s until LEDs flash
simultaneously
both LEDs:
Place object at position
Press push-button for
about 1 s
flash
mutually
Set two way reflective
barrier
Set NOC/NCC
Enable/disable Teach-in
push-button
Switch off power supply
Place reflector at position
Press push-button for about
3 s until LEDs flash
simultaneously
Press button for about 13 s
until LEDs flash
mutually
both LEDs: flash
mutually
Press push-button for
about 10 s
green LED:
yellow LED:
To change output characte-
ristic press push-button
for about 1 s
While pressing the push-
button switch on power
supply
Keep push-button pressed
for about 3 s until both
LEDs flash simultaneously
flashes
on: NOC
off: NCC
green LED:
yellow LED:
flashes
on: push-button
enabled
off: push-button
disabled
To enable/disable Teach-in
press push-button
for about 1 s
Reset to factory setting
Switch off power supply
While pressing the push-
button switch on power
supply
Keep push-button pressed
for about 13 s until both
LEDs stop
flashing
Normal operating mode
Wait for 10 s Wait for 10 s
Normal operating mode
1
1
2
1
85 %
Operating Instructions
sks-15/D sks-15/E
sks-15/CD sks-15/CE
Ultrasonic proximity switch with
one switched output
Ultrasonic Sensors
Product Description
The sks sensor offers a non-contact
measurement of the distance to an
object which must be positioned
within the sensor’s detection zone.
The switched output is set in depen-
dence of the adjusted detect dis-
tance.
Via the push-button, the detect dis-
tance and operating mode can be
adjusted (teach-in). Two LEDs indi-
cate operation and the state of the
switched output.
The output function is changeable
from NOC to NCC.
Safety Notes
Read the operating instructions
prior to start-up.
Connection, installation and
adjustment works may only be
carried out by expert personnel.
No safety component in
accordance with the EU Machine
Directive
Proper use
sks ultrasonic sensors are used for
non-contact detection of objects.
Installation
Mount the sensor at the installa-
tion site.
Maximum torque: 0,5 Nm
Connect a connection cable to the
M8 device plug.
Fig. 2: Pin assignment with view onto sensor
plug and colour coding of the
microsonic connection cable
3-pin initiator plug
1
+U
B
colour
brown
3
4
4-pin initiator plug
-U
B
D
blue
black
colour
1
3
4
2
+U
B
-U
B
brown
blue
D
Com
black
white
1
4
3
1
4
3
2
Start-Up
Connect the power supply.
Carry out the adjustment in
accordance with the diagram.
Factory Setting
Operation with one detect point
Switched output on NOC
Detect points at operating range
Operating modes
Three operating modes are available
for the switched output:
Operation with one detect point
The switched output is set if the ob-
ject falls below the set detect point.
Window mode
The switched output is set if the ob-
ject is within the set window mar-
gins.
Two-way reflective barrier
The switched output is set if the ob-
ject is between sensor and reflector.
Checking operation mode
In normal mode shortly press the
push-button.
The green LED stops shining for one
second, then it will show the current
operation mode:
1 x flashing = operation with one
switching point
2 x flashing = window mode
3 x flashing = reflective barrier
After a break of 3 s the green LED
shows the output function:
1 x flashing = NOC
2 x flashing = NCC
Maintenance
microsonic sensors are maintenance-
free. In case of excess caked-on dirt
we recommend cleaning the white
sensor surface
Notes
sks-15/CD and sks-15/CE sensors
have internal temperature com-
pensation. Because the sensors
heat up on their own, the tempe-
rature compensation reaches its
optimum working point after ap-
proximatly 30 minutes of operati-
on.
The sensors sks-15/D and sks-15/E
have no temperature compensati-
on.
The sks sensor has a blind zone,
within which distance measure-
ments are not possible.
In the normal operating mode, an il-
luminated yellow LED signals the
switched output is switched
through.
If the object to be sensed moves
into the detection area from the
side, the switching distance should
be set 8-10 % further than the de-
sired switch point to obtain a reli-
able object detection.
If the object moves towards the
sensor (e.g. level control) the de-
tect point can be taught to the ac-
tual distance at which the sensor
has to switch the output.
Set switched output
Further settings
Page view 0
1 2

Summary of Contents

Page 1 - Ultrasonic Sensors

Sensor adjustment with Teach-in procedureSet detect pointPlace object at position ➀Press push-button for about3 s until LEDs flash simultaneously both

Page 2

Technical dataBlind zoneOperating rangeMaximum rangeAngle of beam spread20 mm150 mm20 mm150 mm250 mmSee detection zone250 mmSee detection zoneTransduc